96,90€(Kaina be PVM)117,25€(Kaina su PVM)
| Tipas: Maršrutizatorius | |
| Modelis: Teltonika RUTM08 | |
| Jungtys: 1 x WAN, 3 x LAN, 4 x RJ45 (1000 Mbps), 1 x USB Type A | |
| Atmintis: 256 MB DDR3 RAM, 16 MB NOR + 256 MB NAND Flash | |
| Operacinė sistema: RutOS | |
| Maitinimo įėjimas: 1 x 4-pin DC (8–50 VDC) | |
| Maitinimo išėjimas: 1 x 50 V 300 mA | |
| Palaikymas: DLMS | |
| Darbo temperatūra: -40…75°C |
Neturime
| WAN | 1 x WAN port 10/100/1000 Mbps, compliance with IEEE 802.3, IEEE 802.3u, 802.3az standards, supports auto MDI/MDIX crossover |
| LAN | 3 x LAN ports, 10/100/1000 Mbps, compliance with IEEE 802.3, IEEE 802.3u, 802.3az standards, supports auto MDI/MDIX crossover |
| Maršrutas | Static routing, Dynamic routing (BGP, OSPF v2, RIP v1/v2, EIGRP, NHRP), Policy based routing |
| Protokolai | TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, SFTP, FTP, SMTP, SSL/TLS, ARP, VRRP, PPP, PPPoE, UPNP, SSH, DHCP, Telnet, SMPP, SNMP, MQTT, Wake On Lan (WOL), VXLAN |
| VoIP praėjimo parama | H.323 and SIP-alg protocol NAT helpers, allowing proper routing of VoIP packets |
| Ryšio stebėjimas | Ping Reboot, Wget Reboot, Periodic Reboot, LCP and ICMP for link inspection |
| Ugniasienė | Port forward, traffic rules, custom rules, TTL target customisation |
| Ugniasienės būsenos puslapis | View all your Firewall statistics, rules, and rule counters |
| Prievadų valdymas | View device ports, enable and disable each of them, turn auto-configuration on or off, change their transmission speed, and so on |
| Tinklo topologija | Visual representation of your network, showing which devices are connected to which other devices |
| DHCP | Static and dynamic IP allocation, DHCP relay, DHCP server configuration, status, static leases: MAC with wildcards |
| QoS / išmanusis eilių valdymas (SQM) | Traffic priority queuing by source/destination, service, protocol or port, WMM, 802.11e |
| DDNS | Supported >25 service providers, others can be configured manually |
| DNS per HTTPS | DNS over HTTPS proxy enables secure DNS resolution by routing DNS queries over HTTPS |
| Tinklo atsarginės kopijos | VRRP, Wired options, each of which can be used as an automatic Failover |
| Apkrovos balansavimas | Balance Internet traffic over multiple WAN connections |
| Viešosios interneto prieigos taškas | Captive portal (hotspot), internal/external Radius server, Radius MAC authentication, SMS authorisation, SSO authentication, internal/external landing page, walled garden, user scripts, URL parameters, user groups, individual user or group limitations, user management, 9 default customisable themes and optionality to upload and download customised hotspot themes |
| SSHFS | Possibility to mount remote file system via SSH protocol |
| VRF support | Initial virtual routing and forwarding (VRF) support |
| Eismo valdymas | Real-time monitoring, wireless signal charts, traffic usage history |
| 802.1x | Port-based network access control client |
| Autentifikavimas | Pre-shared key, digital certificates, X.509 certificates, TACACS+, Internal & External RADIUS users authentication, IP & login attempts block, time-based login blocking, built-in random password generator |
| Ugniasienė | Preconfigured firewall rules can be enabled via WebUI, unlimited firewall configuration via CLI, DMZ, NAT, NAT-T, NAT64 |
| Įsilaužimo prevencija | DDOS prevention (SYN flood protection, SSH attack prevention, HTTP/HTTPS attack prevention), port scan prevention (SYN-FIN, SYN-RST, X-mas, NULL flags, FIN scan attacks) |
| VLAN | Port and tag-based VLAN separation |
| WEB filtras | Blacklist for blocking out unwanted websites, Whitelist for specifying allowed sites only |
| Prieigos kontrolė | Flexible access control of SSH, Web interface, CLI and Telnet |
| SSL sertifikatų generavimas | Let’s Encrypt and SCEP certificate generation methods |
| OpenVPN | Multiple clients and a server can run simultaneously, 27 encryption methods |
| OpenVPN šifravimas | DES-CBC 64, RC2-CBC 128, DES-EDE-CBC 128, DES-EDE3-CBC 192, DESX-CBC 192, |
| IPsec | XFRM, IKEv1, IKEv2, with 14 encryption methods for IPsec (3DES, DES, AES128, AES192, AES256, AES128GCM8, AES192GCM8, AES256GCM8, AES128GCM12, AES192GCM12, AES256GCM12, AES128GCM16, AES192GCM16, AES256GCM16) |
| GRE | GRE tunnel, GRE tunnel over IPsec support |
| PPTP, L2TP | Client/Server instances can run simultaneously, L2TPv3, L2TP over IPsec support |
| Stunnel | Proxy designed to add TLS encryption functionality to existing clients and servers without any changes in the program’s code |
| DMVPN | Method of building scalable IPsec VPNs, Phase 2 and Phase 3 and Dual Hub support |
| SSTP | SSTP client instance support |
| ZeroTier | ZeroTier VPN client support |
| WireGuard | WireGuard VPN client and server support |
| Tinc | Tinc offers encryption, authentication and compression in it’s tunnels. Client and server support. |
| Tailscale | Tailscale offers speed, stability, and simplicity over traditional VPNs. Encrypted point-to-point connections using the open source WireGuard protocol |
| Palaikomi režimai | Client, Server |
| Supported connection types | TCP |
| Palaikomi režimai | Server, Client |
| Supported connection types | TCP, USB |
| Pasirinktiniai registrai | MODBUS TCP custom register block requests, which read/write to a file inside the router, and can be used to extend MODBUS TCP Client functionality |
| Palaikomi duomenų formatai | 8-bit: INT, UINT; 16-bit: INT, UINT (MSB or LSB first); 32-bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB, BADC), HEX, ASCII |
| Protokolas | HTTP(S), MQTT, Azure MQTT |
| Data to server | Extract parameters from multiple sources and different protocols, and send them all to a single server; Custom LUA scripting, allowing scripts to utilize the router’s Data to server feature |
| Modbus MQTT Gateway | Allows sending commands and receiving data from MODBUS Server through MQTT broker |
| Palaikomi režimai | Station, Outstation |
| Supported connection | TCP, USB |
| DLMS Support | DLMS – standard protocol for utility meter data exchange |
| Palaikomi režimai | Client |
| Supported connection types | TCP, USB |
| COSEM | Allows to scan meter COSEM objects for automatic detection and configuration |
| Teltonika Networks Web API (beta) support | Expand your device’s possibilities by using a set of configurable API endpoints to retrieve or change data. For more information, please refer to this documentation: https://developers.teltonika-networks.com |
| WEB UI | HTTP/HTTPS, status, configuration, FW update, CLI, troubleshoot, multiple event log servers, firmware update availability notifications, event log, system log, kernel log, Internet status |
| FOTA | Firmware update from server, automatic notification |
| SSH | SSH (v1, v2) |
| El. paštas | Receive email message status alerts of various services |
| TR-069 | OpenACS, EasyCwmp, ACSLite, tGem, LibreACS, GenieACS, FreeACS, LibCWMP, Friendly tech, AVSystem |
| MQTT | MQTT Broker, MQTT publisher |
| SNMP | SNMP (v1, v2, v3), SNMP Trap, Brute force protection |
| JSON-RPC | Management API over HTTP/HTTPS |
| RMS | Teltonika Remote Management System (RMS) |
| Cumulocity – Cloud of Things | Allows monitoring of: Device Model, Revision and Serial Number, WAN Type and IP. Has reboot and firmware upgrade actions |
| Azure IoT Hub | Can be configured with Data to Server to send all the available parameters to the cloud. Has Direct method support which allows to execute RutOS API calls on the IoT Hub. Also has Plug and Play integration with Device Provisioning Service that allows zero-touch device provisioning to IoT Hubs |
| Procesorius | MediaTek, Dual-Core, 880 MHz, MIPS1004Kc |
| RAM | 256MB, DDR3 |
| FLASH saugykla | 16 MB serial NOR flash, 256 MB serial NAND flash |
| WEB UI | Update FW from file, check FW on server, configuration profiles, configuration backup |
| FOTA | Update FW |
| RMS | Update FW/configuration for multiple devices at once |
| Nustatymų įsiminimas | Update FW without losing current configuration |
| Factory settings reset | A full factory reset restores all system settings, including the IP address, PIN, and user data to the default manufacturer’s configuration |
| Operacinė sistema | RutOS (OpenWrt based Linux OS) |
| Kalbos | Busybox shell, Lua, C, C++ |
| Kūrėjo įrankiai | SDK package with build environment provided |
| GPL customization | You can create your own custom, branded firmware and web page application by changing colours, logos, and other elements in our firmware to fit your or your clients’ needs |
| Package Manager | The Package Manager is a service used to install additional software on the device |
| Duomenų perdavimas | USB 2.0 |
| Nadojimas | Samba share, USB-to-serial |
| Išoriniai įrenginiai | Possibility to connect external HDD, flash drive, additional modem, printer, USB-serial adapter |
| Vidinės atminties formatas | FAT, FAT32, exFAT, NTFS (read-only), ext2, ext3, ext4 |
| įvestis | 1 x Digital Input, 0 – 6 V detected as logic low, 8 – 50 V detected as logic high |
| išvestis | 1 x Digital Output, Open collector output, max output 50 V, 300 mA |
| Įvykiai | Email, RMS |
| I/O jungiklis | Allows to set certain I/O conditions to initiate event |
| Jungtys | 4-pin industrial DC power socket |
| Įeinančios įtampos diapazonas | 9 – 50 VDC, reverse polarity protection, surge protection >51 VDC 10us max |
| PoE (pasyvus) | Possibility to power up through LAN1 port, not compatible with IEEE802.3af, 802.3at and 802.3bt standards, Mode B, 9 – 50 VDC |
| Energijos naudojimas | Idle: < 1.8 W / Max: < 5.5 W |
| Ethernet | 4 x RJ45 ports, 10/100/1000 Mbps |
| I/O’s | 1 x Digital Input, 1 x Digital Output on 4-pin power connector |
| Būsenos LED indikatoriai | 8 x LAN status LEDs, 1 x Power LED |
| Energija | 1 x 4-pin power connector |
| USB | 1 x USB A port for external devices |
| Perkrovimas | Reboot/User default reset/Factory reset button |
| Kita | 1 x Grounding screw |
| Korpusas | Anodized aluminum housing and panels |
| Matmenys (P x A x G) | 115 x 32.2 x 95.2 mm |
| Svoris | 353 g |
| Montavimas | DIN rail, wall mount, flat surface (all require additional kit) |
| Darbo temperatūra | -40 °C to 75 °C |
| Drėgmė | 10% to 90% non-condensing |
| IP reitingas | IP30 |
| Reguliavimas | CE, UKCA, RCM, CB |
| Standartai | EN 55032:2015+A11:2020 |
| ESD | EN 61000-4-2: 2009 |
| Radiated Immunity | EN IEC 61000-4-3:2020 |
| EFT | EN 61000-4-4: 2012 |
| Surge Immunity (AC Mains Power Port) | EN 61000-4-5:2014 + A1:2017 |
| CS | EN 61000-4-6:2014 |
| DIP | EN IEC 61000-4-11:2020 |
| Standartai | IEC 62368-1:2018 |
| Standartai | CE: EN IEC 62368-1:2020 + A11:2020, EN IEC 62311:2020 |
| Gamintojas |
|---|