| Modelis | LPV-20-12 |
| DC įtampa | 12V |
| Nominali srovė | 1.67A |
| Srovės diapazonas | 0 ~ 1.67A |
| Galia | 20W |
| Sviravimai ir triukšmas (maks.) | 120mVp-p |
| Įtampos tolerancija | ±5.0% |
| Linijinė reguliacija | ±1.0% |
| Apkrovos reguliacija | ±2.0% |
| Nustatymo ir įsijungimo laikas | 500ms, 20ms / 230VAC; 500ms, 20ms / 115VAC at full load |
| Hold Up Time | 50ms / 230VAC; 16ms / 115VAC at full load |
| Įtampos diapazonas | 90 ~ 264VAC, 127 ~ 370VDC |
| Dažnių diapazonas | 47 ~ 63Hz |
| Našumas (tip.) | 81% |
| Kintamoji srovė (tip.) | 0.55A / 115VAC, 0.35A / 230VAC |
| Įjungimo srovė (tip.) | 70A at 230VAC (cold start) |
| Leakage Current | 0.25mA / 240VAC |
| Perkrovos apsauga | 110 ~ 150% rated output power, hiccup mode, auto recovery |
| Viršįtampos apsauga | 13.8 ~ 16V, shut off output, clamping by zener diode |
| Įtampos atlaikymas | I/P-O/P: 3KVAC |
| Izoliacijos varža | I/P-O/P: >100M Ohms / 500VDC / 25℃ / 70% RH |
| Darbinė temperatūra | -30 ~ +70℃ (Refer to Derating Curve) |
| Darbinė drėgmė | 20 ~ 90% RH non-condensing |
| Storage Temperature & Humidity | -40 ~ +80℃, 10 ~ 95% RH |
| Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibracija | 10 ~ 500Hz, 2G 10min./1cycle, 60min. on X, Y, Z axes |
| MTBF | 6025.8K hrs min. (Telcordia SR-332); 786.5K hrs min. (MIL-HDBK-217F, 25℃) |
| Išmatavimai | 118 x 35 x 26 mm (L x W x H) |
| Sertifikatai | UL879, UL1310, CSA C22.2, IEC/EN 62368-1, IS 15885, IP67, EAC TP TC 004 |
| EMC spinduliuotė | EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3, EAC TP TC 020 |
| EMC atsparumas | EN61000-4-2,3,4,5,6,8,11; EN55035; light industry level, EAC TP TC 020 |
| Pakuotė | 0.20Kg/unit; 60pcs/13.3Kg/0.74CUFT |
| Savybės | Constant voltage design, universal AC input/full range, 300VAC surge input withstand (5 sec), protections: short circuit/overload/overvoltage, cooling by free air convection, compact size, fully encapsulated with IP67, isolated plastic case, Class II, LPS certified, suitable for LED fixtures or appliances, 100% full load burn-in test, high reliability, 2-year warranty |
| Max. No. of PSUs on 16A Circuit Breaker | 8 units (Type B) / 14 units (Type C) at 230VAC |