| Modelis | GS1018PS2 |
| Ethernet prievadai | 16× Gigabit PoE ports, 2× Uplink Gigabit ports, 2× Gigabit SFP slots |
| PoE standartai | IEEE802.3af (15.4W), IEEE802.3at (30W) |
| PoE išėjimo įtampa | DC 44–57V |
| PoE maitinimo šerdis | Pins 1/2 (+), 3/6 (–) |
| Įrenginio maksimali PoE galia | 180W |
| Max Non-PoE Power Consumption | 10W |
| Power Supply Input | AC 100–240V, 50/60Hz; Output: 52V / 3.84A |
| Lustų rinkinys | EN8850DH, RTL8238B |
| Perjungimo talpa | 40 Gbps |
| Paketų perdavimo sparta | 29.76 Mpps |
| Paketų buferis | 3 Mbit |
| MAC adresų lentelė | 8K |
| Transfer Mode | Store-and-forward |
| Palaikomi protokolai | IEEE802.3, 802.3u, 802.3ab, 802.3x, 802.3z |
| Extend Mode | Ports 9–16 force 10 Mbps up to 250 m, watchdog enabled for ports 1–16 |
| PoE Priority | Prioritization enabled on ports 1–16 by default |
| Watchdog | Enabled in Extend mode (auto-reboots unresponsive clients) |
| LED indikatoriai | PWR, Link/ACT (1–20), PoE Power Status (1–16), DIP switch mode indicator |
| LED PoE Status Indicator | Green: normal; Flashing: 90–95%; Solid: 95–100% usage |
| Cabling Support | 10BASE-T: Cat 3/4/5 UTP/STP (≤100m); 100/1000BASE-TX: Cat 5 or higher UTP/STP (≤100m) |
| Optical Media Support | Multimode: 50/125, 62.5/125, 100/140 µm; Single-mode: 8/125, 8.7/125, 9/125, 10/125 µm |
| Apsauga nuo viršįtampio | Max 4KV (common mode) |
| ESD apsauga | Air: 8KV, Contact: 6KV |
| Darbinė temperatūra | -10°C ~ 50°C |
| Laikymo temperatūra | -40°C ~ 70°C |
| Darbinė drėgmė | 10% ~ 90%, non-condensing |
| Laikymo drėgmė | 5% ~ 95%, non-condensing |
| Matmenys | 320×207×44 mm |